2021.07.08
威力智能
1、 混膠不均勻出現花膠
1. The mixed glue is not uniform and the flower glue appears
檢查黑白膠泵氣源是否正常,一般氣壓在0.4mpa左右。
Check whether the air source of black-and-white rubber pump is normal. Generally, the air pressure is about 0.4MPa.
檢查黑膠白膠壓力是否平衡,白膠壓力大于等于7mpa,黑膠壓力大于等于7mpa。
Check whether the pressure of black glue and white glue is balanced. The pressure of white glue is greater than or equal to 7MPa, and that of black glue is greater than or equal to 7MPa.
檢查比例泵黑白膠配比是否在9到11:1左右。
Check whether the proportion of black and white glue of proportional pump is about 9 to 11:1.
檢查混膠器是否安裝正確,有無部分堵塞(清膠不干凈所致)。
Check whether the mixer is installed correctly and whether it is partially blocked (caused by unclean glue cleaning).
檢查黑膠智能壓力表壓力是否正常。
Check whether the pressure of black glue intelligent pressure gauge is normal.
檢查黑膠氣動開關與電磁閥動作是否正常。
Check whether the black rubber pneumatic switch and solenoid valve operate normally.
2、 打膠不出膠
2. The glue can't come out
檢查氣源壓力是否在0.4-0.65mpa間。壓力過低將導致無法補膠和其他不確定性不穩定
Check whether the air supply pressure is between 0.4 MPa and 0.65Mpa. If the pressure is too low, it will lead to no glue filling and other uncertainties
檢查觸摸屏中編輯功能菜單中的密封不使用功能是否打開。
Check whether the seal not in use function in the edit function menu of the touch screen is turned on.
檢查氣動開關是否阻塞。
Check whether the pneumatic switch is blocked.
檢查黑白膠泵氣動開關和檢測磁性開關及電磁閥動作是否正常。
Check whether the pneumatic switch, magnetic switch and solenoid valve of black and white rubber pump operate normally.
檢查比例泵上的壓力表顯示是否報警,正常壓力在7-35mpa。
Check whether the pressure gauge on the proportional pump displays alarm, and the normal pressure is 7-35mpa.
檢查液壓站是否有壓力,無壓力做如下處理:清洗比例溢流閥。檢查比例控制器是否正常。
Check whether there is pressure in the hydraulic station. If there is no pressure, do the following: clean the proportional relief valve. Check whether the proportional controller is normal.
清洗時是否能排出白膠。
Whether the white glue can be discharged during cleaning.
檢查比例泵下限開關是否導通。
Check whether the lower limit switch of proportional pump is on.
3、 刮板報警
3. Scraper alarm
檢查膠頭探測傳感器位置是否正常。線路有無斷路。
Check whether the position of rubber probe sensor is normal. Check whether the circuit is open.
氣源壓力是否在0.6-0.8mpa間。
Whether the air supply pressure is between 0.6 MPa and 0.8 MPa.
氣缸支撐桿是否有膠。
Check whether there is glue in the cylinder support rod.
氣缸缸體是否損壞。
Check whether the cylinder block is damaged.
掛板離膠是否過近。
Whether the hanging board is too close to the glue.
4、 伺服異常報警
4. Servo abnormal alarm
A810需廠家現場復位。
A810 needs to be reset by the manufacturer.
AC90檢查伺服電機到驅動器間電纜(東力、反饋、抱閘)是否損壞。
AC90 check whether the cables (Dongli, feedback and holding brake) from servo motor to driver are damaged.
A910、710伺服過載。檢查伺服電機與連接處是否有阻力,手動是否能轉動。
A910, 710 servo overload. Check whether there is resistance between the servo motor and the joint, and whether the manual can rotate.
5、 玻璃測量不準
5. Inaccurate glass measurement
中空線與封膠線承接玻璃時是否有停頓現象。中空線與封膠線段速度是否相同。
Whether there is a pause phenomenon when the air line and sealing line undertake the glass. Whether the speed of the first section of the air line and the sealing line is the same.
6、 膠多或膠少
6. More or less glue
速度異常的忽快忽慢。掃描器沒有順利探測到鋁條中央。
The speed is unusually fast and slow. The scanner failed to detect the center of the aluminum strip.
黑白膠壓力忽大忽小導致涂膠量不穩。檢測液壓站壓力是否正常,補膠動作是否正常。檢查膠路壓力或有無阻塞現象。
Black and white glue pressure fluctuates, resulting in unstable amount of glue. Check whether the pressure of the hydraulic station is normal and whether the glue filling action is normal. Check the rubber circuit pressure or blockage.
玻璃厚度和鋁條厚度設定是否正確。
Whether the glass thickness and aluminum strip thickness are set correctly.
單邊上邊異常,請觀察設備調平是否良好。
If the upper part of one side is abnormal, please observe whether the leveling of the equipment is good.
玻璃錯片嚴重,導致膠咀不能正常貼靠或探測器不能正常探測。
The glass is seriously misplaced, which leads to the failure of the glue nozzle to be attached or the failure of the detector to detect.
7、 補膠補不上
7. The glue can't be mended
膠泵動作時間和次數是否異常。
Whether the action time and times of rubber pump are abnormal.
8、 光電感應異常
8. Abnormal photoelectric induction
看是否有陽光或強光照射。
See if there is sunlight or strong light.
9、 掛板動作異常
9. Abnormal hanging board action
10、 膠附著力差。膠希,更換膠。膠稠,更換膠。
10. The adhesive force is poor. Change the glue. Glue thick, change glue.
檢查掛板離膠頭距離。
Check the distance between the hanging plate and the rubber head.
檢查掛板氣缸感應開關是否正常。
Check whether the sensing switch of hanging plate cylinder is normal.
11、 凝固時間長。檢查配比是否恰當。
11. The setting time is long. Check whether the ratio is appropriate.